How Can We Help?

C1146 (bizhub C650i/C550i/C450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1146: Trailing edge stopper motor/Rr drive malfunction (When FS-540 or FS-540SD is installed)
RankB
Trouble detection condition-The trailing edge stopper sensor/Rr (PS7) is not turned OFF (unblocked) after the set period of time has elapsed after the trailing edge stopper drive starts from the home position
-The trailing edge stopper sensor/Rr (PS7) is not turned ON (blocked) after the set period of time has elapsed after the trailing edge stopper motor/Rr (M11) is energized when the trailing edge stopper returned to the home position.
Trouble isolation
Relevant electrical parts-Trailing edge stopper motor/Rr (M11)
-Trailing edge stopper sensor/Rr (PS7)
-FS control board (FSCB)

Procedure

  1. Check the connector between M11-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.
  2. Check the connector of M11 for proper drive coupling and correct as necessary.
  3. Check the connector between PS7-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.
  4. PS7 I/O check, sensor check
    • Control signal: FSCB J21-16 (ON)
    • Location of electrical component: FS-540/FS-540SD 5-D
  5. M11 operation check
    • Control signal: FSCB J21-17 to 20
    • Location of electrical component: FS-540/FS-540SD 5-D
  6. Replace M11. (Part# A87HPPAD00)
  7. Replace FSCB. (Part# AAR5PPD401)

L.3.8.28 (Link to the Field Service Manual)

Table of Contents