How Can We Help?

C1152 (bizhub 754e/654e)

You are here:

Contents

Trouble typePaper transport belt motor’s malfunction
Trouble codeC1152
RankB
Detection timing<When FS-535+SD-512 is installed>
Even after a predetermined period of time has elapsed since the paper transport belt motor (M34) starts operation, the lock signal is not set to L (turning).
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts• Paper transport belt motor (M34)
• SD drive board (SDDB)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connectors between M34-relay CN1-FSCB CN42 for proper connection, and correct as necessary.
2Check the connector of M34 for proper drive coupling, and correct as necessary.
3M34 operation checkSDDB CN1-1 to 11SD-512 7-D
4Replace M34 (Part# A0PNM10200)
5FSCB ICP12 conduction check
6Replace SDDB (Part# A3ERPP6J03)
7Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.32 (Link to the Field Service Manual)

Table of Contents