How Can We Help?
C1152 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1152: Paper transport belt motor malfunction (When FS-540SD is installed) |
Rank | B |
Trouble detection condition | Even after a predetermined period of time has elapsed since the paper transport belt motor (M134) starts operation, the lock signal is not set to L (turning). |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Paper transport belt motor (M134) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
- Check the connector between M134-relay CN21-FSCB J24 for proper connection and correct as necessary.
- Check the connector of M134 for proper drive coupling and correct as necessary.
- M134 operation check
- Control signal: FSCB J24-1 to 11
- Location of electrical component: FS-540/FS-540SD 7-M
- Replace M134. (Part# A0PNM10200)
- Replace SDCB. (Part# A3ERPP6J03)
- FSCB F4 or F8 conduction check
- Replace FSCB. (Part# AAR5PPD401)