C1182 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Shift motor drive malfunction | |
Trouble code | C1182 | |
Rank | B | |
Detection timing | <When JS-506 is installed> • The tray shift home sensor (PS1) is not unblocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the home position.) • The tray shift home sensor (PS1) is not blocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the shift position.) | |
Trouble isolation | Staple | |
Relevant electrical parts | • Tray shift motor (M1) • Tray shift home sensor (PS1) • JS control board (JSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M1-JSCB CN208 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M1 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS1-JSCB CN208 for proper connection and correct as necessary. | – | – |
4 | PS1 I/O check, sensor check | JSCB CN208-5 (ON) | JS-506 5-C |
5 | M1 operation check | JSCB CN208-1 (DRV) | JS-506 4 to 5-C |
6 | Replace M1 (Part# A2YVR70000) | – | – |
7 | JSCB ICP3 conduction check | – | – |
8 | Replace JSCB (Part# A2YVH10102) | – | – |
- Link to the wiring diagram (N.2.9 JS-506)
- Link to the layout drawings for related parts by each trouble code (S.30. C1182)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.18 (Link to the Field Service Manual)