C1195 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Paper discharge control motors malfunction | |
Trouble code | C1195 | |
Rank | B | |
Detection timing | <When FS-534+SD-511 is installed> The curl cover detection sensor (PS2) is not blocked or unblocked even after the set period of time has elapsed after the paper discharge control motor (M2) is turned ON. | |
Trouble isolation | Staple | |
Relevant electrical parts | -Paper discharge control motor (M2) -Curl cover detection sensor (PS2) -SD drive board (SDDB) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M2 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary. | – | – |
4 | PS2 I/O check, sensor check | SDDB J5 3 (ON) | SD-511 3-B |
5 | M2 operation check | SDDB J5 4 to 7 | SD-511 3-B |
6 | Replace M2 (Part# A3EPPP5302) | – | – |
7 | Replace SDDB (Part# A3ERPP6J03) | – | – |
8 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.8 SD-511)