C1196 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeCenter fold roller motors malfunction <When FS-534+SD-511 is installed>
Tri-fold guide motors malfunction <When FS-535+SD-512 is installed>
Trouble codeC1196
RankB
Detection timing<When FS-534+SD-511 is installed>
The guide home sensor (PS7) is not blocked or unblocked even after the set period of time has elapsed after the center fold roller motor (M6) is turned ON.

<When FS-535+SD-512 is installed>
The tri-fold guide home sensor (PS7) is not not blocked or unblocked even after the set period of time has elapsed after the tri-fold guide motor (M6) is turned ON.
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts<When FS-534+SD-511 is installed>
• Center fold roller motor (M8)
• Guide home sensor (PS7)
• SD drive board (SDDB)
• FS control board (FSCB)

<When FS-535+SD-512 is installed>
• Tri-fold guide motor (M6)
• Tri-fold guide home sensor (PS7)
• SD drive board (SDDB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M8-SDDB J8 for proper connection, and correct as necessary.
2Check the connector of M8 for proper drive coupling, and correct as necessary.
3Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary.
4PS7 I/O check, sensor checkSDDB J9-6 (ON)SD-511 4-G
5M8 operation checkSDDB J8-11 to 14SD-511 2 to 3-F to G
6Replace M8 (Part# A3ERPP3N00)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A3EPPPBE01)

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M6-SDDB J9 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary.
4PS7 I/O check, sensor checkSDDB J9-6 (ON)SD-512 4-G
5M6 operation checkSDDB J9-7 to 10SD-512 3-F to G
6Replace M6 (Part# A3ERPP5R00)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.37 (Link to the Field Service Manual)