How Can We Help?

C1197 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1197: Tri-folding guide motor malfunction (When FS-534SD is installed)
RankB
Trouble detection conditionThe tri-folding gate home sensor (PS11) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized.
Trouble isolationCenter Stapling/Half-Fold/Tri-Fold
Relevant electrical parts-Tri-folding guide motor (M6)
-Tri-folding gate home sensor (PS11)
-SD drive board (SDDB)
-FS control board (FSCB)

 Procedure

  1. Check the connector between M6-SDDB J9 for proper connection and correct as necessary.
  2. Check the connector of M6 for proper drive coupling and correct as necessary.
  3. Check the connector between PS11-SDDB J8 for proper connection and correct as necessary.
  4. PS11 I/O check, sensor check
    • Control signal: SDDB J8-10 (ON)
    • Location of electrical component: SD-511 3-G
  5. M6 operation check
    • Control signal: SDDB J9-7 to 10
    • Location of electrical component: SD-511 4-F to G
  6. Replace M6. (Part# A3ERPP5R00)
  7. Replace SDDB. (Part# A3ERPP6J03)
  8. Replace FSCB. (Part# A3EPPPBE01)

NOTICE

  • Link to the wiring diagram (SD-511)

K.3.8.22 (Link to the Field Service Manual)