How Can We Help?

C1197 (bizhub 554e/454e)

You are here:

Contents

Trouble typeTri-folding guide motor’s malfunction <When FS-534+SD-511 is installed>
Center fold change motor’s malfunction <When FS-535+SD-512 is installed>
Trouble codeC1197
RankB
Detection timing<When FS-534+SD-511 is installed>
The tri-folding gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized.
<When FS-535+SD-512 is installed>
The center fold change gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the center fold change motor (M8) is energized.
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts<When FS-534+SD-511 is installed>
• Tri-folding guide motor (M6)
• Tri-folding gate home sensor (PS11)
• SD drive board (SDDB)
• FS control board (FSCB)
<When FS-535+SD-512 is installed>
• Center fold change motor (M8)
• Center fold change gate home sensor (PS11)
• SD drive board (SDDB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M6-SDDB J9 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary.
4PS11 I/O check, sensor checkSDDB J8-10 (ON)SD-511 3-G
5M6 operation checkSDDB J9-7 to 10SD-511 4-F to G
6Replace M6 (Part# A3ERPP5R00)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A3EPPPBE01)

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M8-SDDB J8 for proper connection, and correct as necessary.
2Check the connector of M8 for proper drive coupling, and correct as necessary.
3Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary.
4PS11 I/O check, sensor checkSDDB J8-10 (ON)SD-512 2-G
5M8 operation checkSDDB J8-11 to 14SD-512 2-F to G
6Replace M8 (Part# A3EPPP5600)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.38 (Link to the Field Service Manual)

Table of Contents