How Can We Help?

C1197 (bizhub 658e/558e/458e/368e/308e)

You are here:

Contents

Trouble typeC1197: Tri-folding guide motor malfunction
RankB
Trouble detection condition<When FS-536SD or FS-537SD is installed>
The tri-folding gate home sensor (PS11) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M8) is energized.
Trouble isolationCenter Stapling/Half-Fold/Tri-Fold
Relevant electrical parts<When FS-536SD or FS-537SD is installed>
• Tri-folding guide motor (M8)
• Tri-folding gate home sensor (PS11)
• SD control board (SDCB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M8-SDCB J8 for proper connection and correct as necessary.
  2. Check the connector of M8 for proper drive coupling and correct as necessary.
  3. Check the connector between PS11-SDCB J8 for proper connection and correct as necessary.
  4. PS11 I/O check, sensor check
    • Control signal: SDCB J8-10 (ON)
    • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 3-P
  5. M8 operation check
    • Control signal: SDCB J8-11 to 14
    • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 2-P
  6. Replace M8. (FS-536SD Part# A3ERPP5R00/ FS-537SD Part# A3ERPP5R00)
  7. Replace SDCB. (FS-536SD / FS-537SD) (Part# A3ERPP6J03)
  8. Replace FSCB. (FS-536SD Part# A87GPP0V00/ FS-537SD Part# A87HPP9M01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.35 (Link to the Field Service Manual)

Table of Contents