C1197 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1197: Tri-folding guide motor malfunction (When FS-534SD is installed) |
Rank | B |
Trouble detection condition | The tri-folding gate home sensor (PS11) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Tri-folding guide motor (M6) -Tri-folding gate home sensor (PS11) -SD drive board (SDDB) -FS control board (FSCB) |
Procedure
- Check the connector between M6-SDDB J9 for proper connection and correct as necessary.
- Check the connector of M6 for proper drive coupling and correct as necessary.
- Check the connector between PS11-SDDB J8 for proper connection and correct as necessary.
- PS11 I/O check, sensor check
- Control signal: SDDB J8-10 (ON)
- Location of electrical component: SD-511 3-G
- M6 operation check
- Control signal: SDDB J9-7 to 10
- Location of electrical component: SD-511 4-F to G
- Replace M6. (Part# A3ERPP5R00)
- Replace SDDB. (Part# A3ERPP6J03)
- Replace FSCB. (Part# A3EPPPBE01)
NOTICE
- Link to the wiring diagram (SD-511)
K.3.8.22 (Link to the Field Service Manual)