How Can We Help?

C1197 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeTri-folding guide motors malfunction
Trouble codeC1197
RankB
Detection timing<When FS-534+SD-511 is installed>
The tri-folding gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized.
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts-Tri-folding guide motor (M6)
-Tri-folding gate home sensor (PS11)
-SD drive board (SDDB)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M6-SDDB J9 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary.
4PS11 I/O check, sensor checkSDDB J8-10 (ON)SD-511 3-G
5M6 operation checkSDDB J9 7 to 10SD-511 4-F to G
6Replace M6 (Part# A3ERPP5R00)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A3EPPPBE01)
  • Link to the wiring diagram (N.2.8 SD-511)
  • Link to the layout drawings for related parts by each trouble code (S.34. C1197)

K3.6.22 (Link to the Field Service Manual)