C1197 (bizhub C658/C558/C458)
Contents
Trouble type | C1197: Tri-folding guide motor’s malfunction | |
Rank | B | |
Trouble detection condition | <When FS-536SD or FS-537SD is installed> | The tri-folding gate home sensor (PS11) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M8) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold | |
Relevant electrical parts | <When FS-536SD or FS-537SD is installed> | •Tri-folding guide motor (M8) • Tri-folding gate home sensor (PS11) • SD control board (SDCB) • FS control board (FSCB) |
Procedure
- Check the connector between M8-SDCB J8 for proper connection and correct as necessary.
- Check the connector of M8 for proper drive coupling and correct as necessary.
- Check the connector between PS11-SDCB J8 for proper connection and correct as necessary.
- PS11 I/O check, sensor check
- Control signal: SDCB J8-10 (ON)
- Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 3-P
- M8 operation check
- Control signal: SDCB J8-11 to 14
- Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 2-P
- Replace M8. (FS-536SD Part# A3EPPP5500 / FS-537SD Part# A87HPPA700)
- Replace SDCB. (FS-536SD Part# A3EP560100 / FS-537SD Part# A3ERPP6J03)
- Replace FSCB. (FS-536SD Part# A87GPP0V00 / FS-537SD Part# A87HPP9M01)
NOTICE
- Link to the wiring diagram (FS-536/FS-536SD)
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.10.35 (Link to the Field Service Manual)