C1197 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC1197: Tri-folding guide motor’s malfunction
RankB
Trouble detection condition<When FS-536SD or FS-537SD is installed>The tri-folding gate home sensor (PS11) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M8) is energized.
Trouble isolationCenter Stapling/Half-Fold/Tri-Fold
Relevant electrical parts<When FS-536SD or FS-537SD is installed>•Tri-folding guide motor (M8)
• Tri-folding gate home sensor (PS11)
• SD control board (SDCB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M8-SDCB J8 for proper connection and correct as necessary.
  2. Check the connector of M8 for proper drive coupling and correct as necessary.
  3. Check the connector between PS11-SDCB J8 for proper connection and correct as necessary.
  4. PS11 I/O check, sensor check
    • Control signal: SDCB J8-10 (ON)
    • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 3-P
  5. M8 operation check
    • Control signal: SDCB J8-11 to 14
    • Location of electrical component: FS-536/FS-536SD 3-P, FS-537/FS-537SD 2-P
  6. Replace M8. (FS-536SD Part# A3EPPP5500 / FS-537SD Part# A87HPPA700)
  7. Replace SDCB. (FS-536SD Part# A3EP560100 / FS-537SD Part# A3ERPP6J03)
  8. Replace FSCB. (FS-536SD Part# A87GPP0V00 / FS-537SD Part# A87HPP9M01)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.35 (Link to the Field Service Manual)