C1197 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539SD is installed
Contents
Trouble type | C1197: Tri-folding guide motor malfunction (When FS-539SD is installed) |
Rank | B |
Trouble detection condition | The tri-folding gate home sensor (PS111) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M108) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Tri-folding guide motor (M108) -Tri-folding gate home sensor (PS111) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
- Check the connector between M108-SDCB J8 for proper connection and correct as necessary.
- Check the connector of M108 for proper drive coupling and correct as necessary.
- Check the connector between PS111-SDCB J8 for proper connection and correct as necessary.
- PS111 I/O check, sensor check
- Control signal: SDCB J8-10 (ON)
- Location of electrical component: FS-539/FS-539SD 3-P
- M108 operation check
- Control signal: SDCB J8-11 to 14
- Location of electrical component: FS-539/FS-539SD 3-P
- Replace M108. (Part# A3EPPP5600)
- Replace SDCB. (Part# A3ERPP6J03)
- Replace FSCB. (Part# A3EP560100)
When FS-540SD is installed
Contents
Trouble type | C1197: Tri-folding guide motor malfunction (When FS-540SD is installed) |
Rank | B |
Trouble detection condition | The tri-folding gate home sensor (PS111) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M108) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | -Tri-folding guide motor (M108) -Tri-folding gate home sensor (PS111) -SD control board (SDCB) -FS control board (FSCB) |
Procedure
- Check the connector between M108-SDCB J8 for proper connection and correct as necessary.
- Check the connector of M108 for proper drive coupling and correct as necessary.
- Check the connector between PS111-SDCB J8 for proper connection and correct as necessary.
- PS111 I/O check, sensor check
- Control signal: SDCB J8-10 (ON)
- Location of electrical component: FS-540/FS-540SD 3-P
- M108 operation check
- Control signal: SDCB J8-11 to 14
- Location of electrical component: FS-540/FS-540SD 3-P
- Replace M108. (Part# A3EPPP5600)
- Replace SDCB. (Part# A3ERPP6J03)
- Replace FSCB. (Part# AAR5PPE200)