Trouble typeReceiving roller pressure/ retraction motor’s malfunction
Trouble codeC11A2
RankB
Detection timing<When FS-534 is installed>
The receiving roller retraction sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed after the receiving roller retraction motor (M4) is turned ON.
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts• Receiving roller retraction motor (M4)
• Receiving roller retraction sensor (PS11)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M4-FSCB J4 for proper connection, and correct as necessary.
2Check the connector of M4 for proper drive coupling, and correct as necessary.
3Check the connector between PS11-FSCB J4 for proper connection, and correct as necessary.
4PS11 I/O check, sensor checkFSCB J4<B>-16 (ON)FS-534 13-C
5M4 operation checkFSCB J4<A>-1 to 4FS-534 11-C to D
6Replace M4 (Part# A3EPPP5600)
7Replace FSCB (Part# A3EPPPBE01)