How Can We Help?

C2152 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeTransfer belt pressure welding alienation
Trouble codeC2152
RankB
Detection timing• At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) or the 1st transfer pressure sensor/YMC (PS52) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
• Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the 1st transfer pressure sensor/K (PS51) or the 1st transfer pressure sensor/YMC (PS52) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
Trouble isolation
Relevant electrical parts• Transfer belt unit
• 1st transfer pressure sensor/K (PS51)
• 1st transfer pressure sensor/YMC (PS52)
• 1st transfer pressure motor (M21)
• Printer control board (PRCB)
OperationPositionSensor status (K: Color)
Color and K retraction -> K pressureColor and K pressure -> K pressureK pressureON (not blocked): OFF (blocked)
Color and K retraction -> Color and K pressureK pressure -> Color and K pressureColor and K pressureON (not blocked): ON (not blocked)
K pressure -> Color and K retractionColor and K pressure -> Color and K retractionColor and K retractionOFF (blocked): OFF (blocked)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M21-relay CN428-PRCB CN4 for proper connection and correct as necessary.
2Check the connector of M21 for proper drive coupling and correct as necessary.
3Check the transfer roller pressure gear of the transfer belt unit for proper engagement and the roller for rolling operation, and correct any faulty motion.
4Check the connector between PS51-relay CN297-PRCB CN6 for proper connection and correct as necessary.
5Check the connector between PS52-relay CN297-PRCB CN6 for proper connection and correct as necessary.
6PS51 I/O check, sensor checkPRCB CN6-1 (ON)21 to 22-C
7PS52 I/O check, sensor checkPRCB CN6-4 (ON)22-C
8M21 operation checkPRCB CN4-9 to 123 to 4-K
9Replace M21 (part# A02EM10C01)
10Replace the transfer belt unit. (Part# A2X0R70100)
11PRCB ICP5 or ICP24 conduction check
12Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.