Trouble typeC2153: Transfer belt spacing fault at K pressure switching
RankB
Trouble detection conditionThe 1st transfer pressure sensor (PS39) does not detect switch from pressure to retraction within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Trouble isolation
Relevant electrical parts-Fusing motor (M3)
-1st transfer pressure clutch (CL5)
-1st transfer pressure sensor (PS39)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M3-MFPB CN11E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. Check the connector between PS39-relay CN24-MFPB CN7E for proper connection and correct as necessary.
  4. Check the connector between CL5-relay CN29-MFPB CN12E for proper connection and correct as necessary.
  5. PS39 I/O check, sensor check
    • Control signal: MFPB CN7E<B>-13 (ON)
    • Location of electrical component: 22-C
  6. CL5 operation check
    • Control signal: MFPB CN12E-12 (ON)
    • Location of electrical component: 5-C
  7. M3 operation check
    • Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP)
    • Location of electrical component: 3-C
  8. Replace M3. (Part# A7PUM10000)
  9. MFPB F13E conduction check
  10. Replace MFPB. (Part# A797H02118)

NOTICE

K.3.9.1 (Link to the Field Service Manual)