C2153 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2153: Transfer belt spacing fault at K pressure switching |
Rank | B |
Trouble detection condition | The 1st transfer pressure sensor (PS39) does not detect switch from pressure to retraction within a given period time after 1st transfer pressure clutch (CL5) has stared engagement. |
Trouble isolation | – |
Relevant electrical parts | -Fusing motor (M3) -1st transfer pressure clutch (CL5) -1st transfer pressure sensor (PS39) -MFP board (MFPB) |
Procedure
- Check the connector between M3-MFPB CN11E for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check the connector between PS39-relay CN24-MFPB CN7E for proper connection and correct as necessary.
- Check the connector between CL5-relay CN29-MFPB CN12E for proper connection and correct as necessary.
- PS39 I/O check, sensor check
- Control signal: MFPB CN7E<B>-13 (ON)
- Location of electrical component: 22-C
- CL5 operation check
- Control signal: MFPB CN12E-12 (ON)
- Location of electrical component: 5-C
- M3 operation check
- Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP)
- Location of electrical component: 3-C
- Replace M3. (Part# A7PUM10000)
- MFPB F13E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
- Link to the wiring diagram (bizhub C287/C227)
K.3.9.1 (Link to the Field Service Manual)