C2153: Transfer belt spacing fault at K pressure switchingC2154: Transfer belt contact fault at all pressure switchingC2155: Transfer belt contact fault after K pressure establishedC2156: Transfer belt spacing fault after all pressure established
Rank
B
Trouble detection condition
C2153: The 1st transfer pressure switch (SW4) is not turned ON even after the lapse of a given period of time after the retraction operation started.C2154: The 1st transfer pressure switch (SW4) is not turned OFF even after the lapse of a given period of time after the pressure operation started.C2155: The 1st transfer pressure sensor (SW4) is turned OFF after the lapse of given time after the retraction operation is finished.C2156: The 1st transfer pressure sensor (SW4) is turned ON after the lapse of given time after the pressure operation is finished.
Trouble isolation
–
Relevant electrical parts
Color PC motor (M2)1st transfer pressure clutch (CL1)1st transfer pressure switch (SW4)CPU board (CPUB)Base board (BASEB)
Procedure
Check the connector between M2-BASEB CN24E for proper connection and correct as necessary.
Check the connector of M2 for proper drive coupling and correct as necessary.
Check the connector between SW4-BASEB CN18E for proper connection and correct as necessary.
Check the connector between CL1-relay CN13-BASEB CN18E for proper connection and correct as necessary.
Check CPUB for proper installation and correct as necessary.