How Can We Help?

C2156 (bizhub C3320i)

You are here:

Contents

Trouble typeC2156: Transfer belt spacing fault after all pressure established
RankB
Trouble detection conditionThe 1st transfer pressure sensor (SW4) is turned ON after the lapse of given time after the pressure operation is finished.
Trouble isolation
Relevant electrical parts-Color motor (M2)
-1st transfer pressure clutch (CL1)
-1st transfer pressure switch (SW4)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between M2-BASEB CN17E for proper connection and correct as necessary.
  2. Check the connector of M2 for proper drive coupling and correct as necessary.
  3. Check the connector between SW4-BASEB CN18E for proper connection and correct as necessary.
  4. Check the connector between CL1-relay CN13-BASEB CN18E for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. SW4 I/O check, sensor check
    • Control signal: BASEB CN18E-3 (ON)
    • Location of electrical component: 2-C
  7. CL1 load check
    • Check code: 24
    • Multi code: 1
    • Control signal: BASEB CN18E-4 (ON)
    • Location of electrical component: 2-C
  8. M2 load check
    • Check code: 41
    • Multi code: 1, 2
    • Control signal: BASEB CN17E-11 to 15
    • Location of electrical component: 1-C
  9. Replace M2. (Part# AA2JM11100)
  10. Replace CPUB. (Part# AAJRH01005)
  11. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.