How Can We Help?

C2253 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC2253: Main motor failure to turn
RankB
Trouble detection conditionThe motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolation
Relevant electrical parts-Main motor (M3)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M3-MFPB CN19E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. M3 operation check
    • Control signal: MFPB CN19E-10 to 14
    • Location of electrical component: 26-C
  4. Replace M3. (Part# A61DM10200)
  5. MFPB F11E conduction check
  6. Replace MFPB. (Part# A7AHH0201D)

NOTICE

K.3.9.1 (Link to the Field Service Manual)

Table of Contents