How Can We Help?

C2256 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC2256: Developing motor/YMC turning at abnormal timing
RankB
Trouble detection conditionThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Imaging unit/C
-Imaging unit/M
-Imaging unit/Y
-Developing motor/YMC (M17)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M17-MFPB CN10E, CN16E for proper connection and correct as necessary.
  2. Check the connector of M17 for proper drive coupling and correct as necessary.
  3. M17 load check
    • Check code: 50
    • Multi code: 2, 3, 4
    • Control signal: MFPB CN16E-1 (DC24V), MFPB CN10E<B>-9 (START/STOP)
    • Location of electrical component: 6-K
  4. Replace M17. (Part# A61DM10301)
  5. Replace the imaging unit/Y,M,C. (C Part# A9K70KD, M Part# A9K70ED, Y Part# A9K708D)
  6. MFPB F9E conduction check
  7. Replace MFPB. (Part# A8JEH02002)

L.3.9.5 (Link to the Field Service Manual)

Table of Contents