C2256 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2256: Developing motor/YMC turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Imaging unit/C -Imaging unit/M -Imaging unit/Y -Developing motor/YMC (M17) -MFP board (MFPB) |
Procedure
- Check the connector between M17-MFPB CN10E, CN16E for proper connection and correct as necessary.
- Check the connector of M17 for proper drive coupling and correct as necessary.
- M17 load check
- Check code: 50
- Multi code: 2, 3, 4
- Control signal: MFPB CN16E-1 (DC24V), MFPB CN10E<B>-9 (START/STOP)
- Location of electrical component: 6-K
- Replace M17. (Part# A61DM10301)
- Replace the imaging unit/Y,M,C. (C Part# A9K70KD, M Part# A9K70ED, Y Part# A9K708D)
- MFPB F9E conduction check
- Replace MFPB. (Part# A8JEH02002)
L.3.9.5 (Link to the Field Service Manual)