Trouble type | Developing motor/K’s turning at abnormal timing |
Trouble code | C225A |
Rank | B |
Detection timing | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Developing motor/K (M19) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M19-PRCB CN22 for proper connection and correct as necessary. | – | – |
2 | Check the M19 connector for proper drive coupling and correct as necessary. | – | – |
3 | M19 operation check | PRCB CN22-1 to 5 | 16-K |
4 | Replace M19 (Part# A161M10200) | – | – |
5 | PRCB ICP6 conduction check | – | – |
6 | Replace PRCB (Part# A2X0H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
- Link to the layout drawings for related parts by each trouble code (S.58. C2259, C225A)