C225B (bizhub C754e/C654e)

You are here:

Contents

Trouble typePC motor/K’s failure to turn
Trouble codeC225B
RankB
Detection timingThe motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolation
Relevant electrical parts• Drum unit/K
• PC motor/K (M18)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M18-PRCB CN21 for proper connection and correct as necessary.
2Check the M18 connector for proper drive coupling and correct as necessary.
3M18 operation checkPRCB CN21-13 (LOCK)PRCB CN21-10 (REM)16-K
4Replace M18 (Part# A00JM11000)
5Replace the drum unit/K. (Part# A2X20RD)
6PRCB ICP6 or ICP18 conduction check
7Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.10 (Link to the Field Service Manual)