Trouble typeC2350: Toner suction fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-Toner suction fan (FM4)
-MFP board (MFPB)

 Procedure

  1. Check the connector between FM4-relay CN46-MFPB CN15E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM4 operation check
    • Control signal: MFPB CN15E-1 (REM), MFPB CN15E-3 (LOCK)
    • Location of electrical component: 16 to 17-C
  4. Replace FM4. (Part# 4139M10000)
  5. MFPB F7E conduction check
  6. Replace MFPB. (Part# A7AHH0201D)