C2350 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Toner suction fan’s failure to turn |
Trouble code | C2350 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Toner suction fan (FM7) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connectors between FM7-relay CN326-PRCB CN2 for proper connection, and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM7 operation check | PRCB CN2-4 (DRIVE)PRCB CN2-6 (LOCK) | 2-K |
4 | Replace FM7 (Part# 9313100072) | – | – |
5 | Replace PRCB (Part# A2X0H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
K.3.7.11 (Link to the Field Service Manual)