How Can We Help?

C2353 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeIU cooling fan’s failure to turn
Trouble codeC2353
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• IU cooling fan (FM15)
• PH relay board (PHRYB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connectors between FM15-relay CN707-PHRYB CN13 for proper connection, and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM15 operation checkPHRYB CN5-1 (REM)PHRYB CN5-3 (LOCK)7-B
4Replace FM15 (Part# 9313110033)
5PHRYB ICP6 conduction check
6Replace PHRYB (Part# A2X0H00300)
7Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.12 (Link to the Field Service Manual)