C2353 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2353: IU cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -IU cooling fan (FM15) -PH relay board (PHRYB) |
Procedure
- Check the connector between FM15-relay CN707-PHRYB CN13 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM15 load check
- Check code: 42
- Multi code: 4
- Control signal: PHRYB CN13-1 (DRIVE), PHRYB CN13-3 (LOCK)
- Location of electrical component: 8-B
- Replace FM15. (Part# 9313110033)
- PHRYB ICP6 conduction check.
- Replace PHRYB. (Part# A8JEH00301)