How Can We Help?

C2355 (bizhub 554e/454e)

You are here:

Contents

Trouble type Transfer belt cleaner cooling fan failure to turn
Trouble code C2355
Rank B
Detection timing The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts • Transfer belt cleaner cooling fan (FM2)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between FM2-relay CN115-PRCB CN13 for proper connection and correct as necessary.
2 Check the fan for possible overload and correct as necessary.
3 FM2 operation check PRCB CN13-8 (REM) PRCB CN13-10 (LOCK) bizhub C554e 25-C bizhub C454e 23-C
4 Replace FM2
5 PRCB ICP3 conduction check
6 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)

Document Information ID D0001134344 Revise ID R000003