How Can We Help?

C2355 (bizhub 650i/550i/450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC2355: Transfer belt cleaner cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains Low for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-Transfer belt cleaner cooling fan (FM2)
-Expansion control board (EXCB)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between FM2-relay CN115-EXCB CN10EX for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. FM2 load check
    • Check code: 42
    • Multi code: 13, 14
    • Control signal: EXCB CN10EX-9 (REM), EXCB CN10EX-11 (LOCK)
    • Location of electrical component: 22-P
  6. Replace FM2. (Part# A93EM10000)
  7. Replace EXCB. (Part# AC74H00501)
  8. Replace CPUB.
    650i/550i(Part# AC74H02P03)
    450i (Part# AC76H02P02)
  9. Replace BASEB. (Part# AC74H02101)

(Link to the Field Service Manual)

Table of Contents