How Can We Help?

C2355 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC2355: Transfer belt cleaner cooling fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains Low for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Transfer belt cleaner cooling fan (FM2)
• Expansion control board (EXCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between FM2-relay CN115-EXCB CN10EX for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. FM2 load check
    • Check code: 42
    • Multi code: 13, 14
    • Control signal: EXCB CN10EX-9 (REM), EXCB CN10EX-11 (LOCK)
    • Location of electrical component: 11-P
  6. Replace FM2. (Part# A93EM10000)
  7. Replace EXCB. (Part# AA2JH00500)
  8. Replace CPUB. (Part# AA2JH02N06)
  9. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.5 (Link to the Field Service Manual)

Table of Contents