Trouble type | C2355: Transfer belt cleaner cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Transfer belt cleaner cooling fan (FM2) -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM2-relay CN115-EXCB CN10EX for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM2 load check
- Check code: 42
- Multi code: 13, 14
- Control signal: EXCB CN10EX-9 (REM), EXCB CN10EX-11 (LOCK)
- Location of electrical component: 22-P
- Replace FM2. (Part# A93EM10000)
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
L.3.9.6 (Link to the Field Service Manual)