How Can We Help?

C2412 (bizhub C3320i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC2412: Imaging unit/M new article release
RankB
Trouble detection conditionThe status with the new unit is not cleared after the new imaging unit is set.
Trouble isolation
Relevant electrical parts-Imaging unit/C,M,Y,K
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Reinstall the imaging unit.
  2. Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary. (C2411)
  3. Check the connector between the imaging unit/M-relay CN8-BASEB CN14E for proper connection and correct as necessary. (C2412)
  4. Check the connector between the imaging unit/Y-relay CN7-BASEB CN14E for proper connection and correct as necessary. (C2413)
  5. Check the connector between the imaging unit/K-relay CN6-BASEB CN14E for proper connection and correct as necessary. (C2414)
  6. Check CPUB for proper installation and correct as necessary.
  7. Replace the corresponding imaging unit. (Part# AAJV0CE)
  8. Replace CPUB. (Part# AAJRH01005)
  9. Replace BASEB. (Part# A93EH02007)

L.3.7.4 (Link to the Field Service Manual)

Table of Contents