C2413 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Developing unit/Y new article release |
Trouble code | C2413: Developing unit/Y new article release |
Rank | B |
Detection timing | The status with the new unit is not cleared after the new developing unit is set. |
Trouble isolation | – |
Relevant electrical parts | -Developing unit -Front side board (FRB) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Reinstall developing unit | – | – |
2 | Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary. | – | – |
3 | Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. | – | – |
4 | Replace the developing unit (Part# A2XN08D) | – | – |
5 | Replace FRB (Part# A161H00501) | – | – |
6 | Replace PRCB (Part# A161H00108) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.43. C2411, C2552, C2561)
- Link to the layout drawings for related parts by each trouble code (S.44. C2412, C2554, C2562)
- Link to the layout drawings for related parts by each trouble code (S.45. C2413, C2556, C2563)
- Link to the layout drawings for related parts by each trouble code (S.46. C2414, C2558, C2564)
K3.7.5 (Link to the Field Service Manual)