C2413 (bizhub C368/C308/C258)
Contents
Trouble type | C2413: Developing unit/Y new article release |
Rank | B |
Trouble detection condition | The status with the new unit is not cleared after the new developing unit is set. |
Trouble isolation | – |
Relevant electrical parts | • Developing unit • Front side board (FRB) • MFP board (MFPB) |
Procedure
- Reinstall developing unit.
- Check the connector between the developing unit-FRB CN13 (C2414), CN14 (C2411), CN15 (C2412), CN16 (C2413) for proper connection and correct as necessary.
- Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary.
- Replace the developing unit. (Part# A7U408D )
- Replace FRB. (Part# A7PUH00500)
- Replace MFPB. (Part# A7PUH02123)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.11.5 (Link to the Field Service Manual)