How Can We Help?

C2553 (bizhub C3320i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC2553: Abnormally low toner density detected magenta TCR sensor
RankB
Trouble detection conditionWhen sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Trouble isolation
Relevant electrical parts-Imaging unit/C,M,Y,K
-Toner supply motor/YM (M4)
-Toner supply motor/CK (M5)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Perform image troubleshooting procedure if image density is low.
  2. Reinstall the imaging unit.
  3. Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary. (C2551)
  4. Check the connector between the imaging unit/M-relay CN8-BASEB CN14E for proper connection and correct as necessary. (C2553)
  5. Check the connector between the imaging unit/Y-relay CN7-BASEB CN14E for proper connection and correct as necessary. (C2555)
  6. Check the connector between the imaging unit/K-relay CN6-BASEB CN14E for proper connection and correct as necessary. (C2557)
  7. Check the connector between M4-BASEB CN13E for proper connection and correct as necessary.
  8. Check the connector between M5-BASEB CN13E for proper connection and correct as necessary.
  9. Check CPUB for proper installation and correct as necessary.
  10. M4, M5 operation check
    • Control signal: BASEB CN13E-1 to 4 (M4), BASEB CN13E-5 to 8 (M5)
    • Location of electrical component: 4-C
  11. Replace the corresponding imaging unit. (Part# AAJV0CE)
  12. Replace CPUB. (Part# AAJRH01005)
  13. Replace BASEB. (Part# A93EH02007)

L.3.7.5 (Link to the Field Service Manual)