How Can We Help?

C2559 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC2559: Cyan TCR sensor adjustment failure
RankB
Trouble detection conditionTCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Trouble isolation
Relevant electrical parts• Imaging unit/C,M,Y,K
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Reinstall the imaging unit.
  2. Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. Replace the corresponding imaging unit. C4000i/C3300i (C Part# AAJV0HE, M Part# AAJV0CE, Y Part# AAJV06E , K Part# AAJV01E)
  5. Replace CPUB. (C4000i Part# Part# AAJRH01005 / C3300i Part# AAJTH01005)
  6. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.7 (Link to the Field Service Manual)

Table of Contents