Trouble typeC255C: Black TCR sensor adjustment failure
RankB
Trouble detection conditionTCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Trouble isolation
Relevant electrical parts• Developing unit
• Toner cartridge motor/K (M25)
• Toner supply motor/K (M6)
• Front side board (FRB)
• MFP board (MFPB)

 Procedure

  1. Reinstall developing unit.
  2. Check the connector between the developing unit -FRB CN13 for proper connection and correct as necessary.
  3. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary.
  4. M25 operation check
    • Control signal: MFPB CN30E-1 to 4
    • Location of electrical component: 16-C
  5. M6 operation check
    • Control signal: MFPB CN30E-5 to 8
    • Location of electrical component: 17-C
  6. Replace the developing unit. (Part# A7U403D)
  7. Replace FRB. (Part# A9HJH00501)
  8. Replace MFPB. (Part# A9HJH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.5 (Link to the Field Service Manual)