C255C (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC255C: Black TCR sensor adjustment failure
RankB
Trouble detection conditionTCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Trouble isolation
Relevant electrical parts• Developing unit/K
• Toner cartridge motor/CK (M25)
• Toner supply motor/K (M6)
• Expansion control board (EXCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Reinstall the developing unit/K.
  2. Check the connector between the developing unit/K-relay CN252-relay CN25-EXCB CN4EX for proper connection and correct as necessary.
  3. Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
  4. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. M25 operation check
    • Control signal: EXCB CN11EX-1 to 4
    • Location of electrical component: 4-P
  7. M6 operation check
    • Control signal: EXCB CN10EX-16 to 19
    • Location of electrical component: 11-P
  8. Replace the developing unit/K.
  9. Replace EXCB. (Part# AA2JH00500)
  10. Replace CPUB. (Part# AA2JH02N06)
  11. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.11 (Link to the Field Service Manual)