C2561 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2561: Cyan TCR sensor failure |
Rank | B |
Trouble detection condition | Alarm signals for each TCR sensor is detected more than the predetermined number of times.This detection is used for detecting disconnection of TCR sensor connector. |
Trouble isolation | – |
Relevant electrical parts | -Developing unit/C,M,Y,K -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Reinstall the developing unit.
- Check the connector between the developing unit/C-relay CN251-relay CN248-EXCB CN6EX for proper connection and correct as necessary. (C2561)
- Check the connector between the developing unit/M-relay CN250-relay CN248-EXCB CN6EX for proper connection and correct as necessary. (C2562)
- Check the connector between the developing unit/Y-relay CN249-relay CN248-EXCB CN6EX for proper connection and correct as necessary. (C2563)
- Check the connector between the developing unit/K-relay CN252-relay CN25-EXCB CN4EX for proper connection and correct as necessary. (C2564)
- Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding developing unit. (Part# ACV80KD)
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA2JH02005)
L.3.9.14 (Link to the Field Service Manual)