C2562 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2562: Magenta TCR sensor failure |
Rank | B |
Trouble detection condition | Alarm signals for each TCR sensor is detected more than the predetermined number of times.This detection is used for detecting disconnection of TCR sensor connector. |
Trouble isolation | – |
Relevant electrical parts | -Imaging unit/C,M,Y,K -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Reinstall the imaging unit.
- Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary. (C2561)
- Check the connector between the imaging unit/M-relay CN8-BASEB CN14E for proper connection and correct as necessary. (C2562)
- Check the connector between the imaging unit/Y-relay CN7-BASEB CN14E for proper connection and correct as necessary. (C2563)
- Check the connector between the imaging unit/K-relay CN6-BASEB CN14E for proper connection and correct as necessary. (C2564)
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding imaging unit. (Part# AAJV0CE)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
L.3.7.8 (Link to the Field Service Manual)