C2562 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeMagenta TCR sensor failure
Trouble codeMagenta TCR sensor failure
RankB
Detection timingAlarm signals for a TCR sensor are detected more than the predetermined number of times.This detection is used for detecting disconnection of TCR sensor connector.
Trouble isolation
Relevant electrical parts• Imaging unit /C 
• Imaging unit /M 
• Imaging unit /Y 
• Developing unit /K 
• PH relay board (PHRYB) 
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1• Reinstall the imaging unit /C,/M, /Y
• Reinstall the developing unit /K
2Check the harness from imaging unit /C, /M, /Y and developing unit /K to PHRYB CN2, 3, 4, 5 for proper connection and correct as necessary.
• CN2: Developing unit /K
• CN3: Imaging unit /C
• CN4, CN5: Imaging unit /M, Imaging unit /Y
3• Replace the imaging unit (C Part# A2X20KD, M Part# A2X20ED, Y Part# A2X208D)
• Replace the developing unit /K (Part# A2X203D)
4PRCB ICP 7 conduction check
5Replace PHRYB (Part# A2X0H00300)
6Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.20 (Link to the Field Service Manual)