C2563 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeYellow TCR sensor failure
Trouble codeC2563: Yellow TCR sensor failure
RankB
Detection timingTCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Trouble isolation
Relevant electrical parts• Developing unit/Y,M,C,K 
• Front side board (FRB) 
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Reinstall developing unit
2Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary.
3Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary.
4Replace the developing unit (Part# A2XN08D)
5Replace FRB (Parts# A7PUH00500)
6Replace PRCB (C554e Part# A5AYH00101 / C454e Part# A5C0H00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.10 (Link to the Field Service Manual)