C2650 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2650: Main backup media access error |
Rank | C |
Trouble detection condition | – The re-written data, which has been read out, checked and founded as error, is read out again and found as error. – The error was found when reading out the counter value. – The main body detects that the backup board is not mounted. |
Trouble isolation | – |
Relevant electrical parts | – Backup board (ERB) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check for proper connection between ERB-BASEB CN5E and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace CPUB.
- Replace BASEB.
- Replace ERB.
- If the above actions do not solve the problem, contact KM.