C2A11, C2A12, C2A13, C2A14 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2A11: Drum unit/C new release failure C2A12: Drum unit/M new release failure C2A13: Drum unit/Y new release failure C2A14: Drum unit/K new release failure |
Rank | B |
Trouble detection condition | The status with the new unit is not cleared after the new drum unit is set. |
Trouble isolation | – |
Relevant electrical parts | -Drum unit/C,M,Y,K -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Clean the connection between the drum unit and the main body if dirty.
- Reinstall the drum unit.
- Check the connector between the drum unit/C-relay CN47-relay CN149-EXCB CN4EX for proper connection and correct as necessary. (C2A11)
- Check the connector between the drum unit/M-relay CN46-relay CN149-EXCB CN4EX for proper connection and correct as necessary. (C2A12)
- Check the connector between the drum unit/Y-relay CN45-relay CN149-EXCB CN4EX for proper connection and correct as necessary. (C2A13)
- Check the connector between the drum unit/K-relay CN48-relay CN149-EXCB CN4EX for proper connection and correct as necessary. (C2A14)
- Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding drum unit.
(CMY ACV80TE / K Part# ACV80RE) - Replace EXCB. (Part# AA7NH00500)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)