C2A12 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C2A12: Drum unit/M new release failure |
Rank | B |
Trouble detection condition | The status with the new unit is not cleared after the new drum unit is set. |
Trouble isolation | – |
Relevant electrical parts | • Drum unit/C,M,Y,K • Expansion control board (EXCB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Clean the connection between the drum unit and the main body if dirty.
- Reinstall the drum unit.
- Check the connector between the drum unit/C-relay CN47-relay CN149-EXCB CN4EX for proper connection and correct as necessary. (C2A11)
- Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding drum unit.
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.8.14 (Link to the Field Service Manual)