C2A23 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2A23: Toner cartridge/Y new release failure |
Rank | C |
Trouble detection condition | The status with the new unit is not cleared after the new toner cartridge is set. |
Trouble isolation | – |
Relevant electrical parts | -Toner cartridge/C,M,Y,K -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Reinstall the toner cartridge.
- Clean the connection between the toner cartridge and the main body if dirty.
- Check the connector between the toner cartridge/C-relay CN102-BASEB CN11E for proper connection and correct as necessary. (C2A21)
- Check the connector between the toner cartridge/M-relay CN101-BASEB CN11E for proper connection and correct as necessary. (C2A22)
- Check the connector between the toner cartridge/Y-relay CN100-BASEB CN11E for proper connection and correct as necessary. (C2A23)
- Check the connector between the toner cartridge/K-relay CN103-BASEB CN11E for proper connection and correct as necessary. (C2A24)
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding toner cartridge. (Part# AAJW232)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
L.3.7.10 (Link to the Field Service Manual)