C3101 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3101: Pressure roller pressure failureC3103: Pressure roller release failure |
Rank | B |
Trouble detection condition | -The fusing pressure home sensor (PS59) is not turned ON (pressed state) after the set period of time after the fusing pressure roller pressure operation is started. -The fusing pressure home sensor (PS59) is not ON (pressed state) when the fusing pressure roller pressure operation is completed. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Fusing pressure home sensor (PS59) -Fusing pressure motor (M29) -MFP board (MFPB) |
Procedure
- Check the connector between M29-MFPB CN28E for proper connection and correct as necessary.
- Check the connector of M29 for proper drive coupling and correct as necessary.
- Check the connector between the fusing unit-relay CN260-MFPB CN21E for proper connection and correct or change as necessary.
- PS59 I/O check, sensor check
- Control signal: MFPB CN21E-5 (ON)
- Location of electrical component: 12-C
- M29 load check
- Check code: 45
- Multi code: 7, 8
- Control signal: MFPB CN28E-8 to 11
- Location of electrical component: 7-K
- Replace M29. (Part# A796M10B00)
- Replace the fusing unit. (Part# A8JER70222)
- MFPB F16E conduction check
- Replace MFPB. (Part# A8JEH02002)
L.3.10.1 (Link to the Field Service Manual)