C3102 (bizhub 558/458)
Contents
Trouble type | C3102: Heating roller failure to turn (bizhub 558) |
Rank | A |
Trouble detection condition | The hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller rotation sensor (PS37) • Fusing motor (M3)MFP board (MFPB) |
Procedure
- Check the fusing unit for proper installation and correct as necessary.
- Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check the connector between the fusing unit-relay CN100-MFPB CN13E for proper connection and correct as necessary.
- PS37 I/O check, sensor check
- Control signal: MFPB CN13E-3 (ON)
- Location of electrical component: 23-C
- M3 operation check
- Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
- Location of electrical component: 2-C
- Replace M3. (558)(458)Part# A79JM11300)
- Replace the fusing unit. (558)Part# A79JR71044 )(458)Part# A79MR70222 )
- Replace MFPB. (558)Part# A9HGH02102 )(458)Part # A9HHH02102 )
NOTICE
- Link to the wiring diagram (bizhub 558/458)
Please review all Part Numbers for accuracy and current version.