Trouble typeC3103: Pressure roller release failure
RankB
Trouble detection conditionThe fusing pressure home sensor (PS38) is not turned OFF (unblocked) even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
Trouble isolation
Relevant electrical parts-Fusing unit
-Fusing pressure motor (M11)
-Fusing pressure home sensor (PS38)
-Expansion control board (EXCB)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between M11-relay CN112-EXCB CN14EX for proper connection and correct as necessary.
  2. Check the connector between the fusing unit-relay CN95, CN96-BASEB CN4E for proper connection and correct as necessary.
  3. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. PS38 I/O check, sensor check
    • Control signal: BASEB CN4E-3 (ON)
    • Location of electrical component: 7-C
  6. M11 load check
    • Check code: 45
    • Multi code: 7, 8, 9
    • Control signal: EXCB CN14EX-11 to 14
    • Location of electrical component: 18-P
  7. Replace M11. (Part# A161M10300)
  8. Replace the fusing unit.
    650i (Part# AA7NR70200)
    450i/550i (Part# AA7RR70700)
  9. Replace EXCB. (Part# AC74H00501)
  10. Replace CPUB.
    650i/550i(Part# AC74H02P03)
    450i (Part# AC76H02P02)
  11. Replace BASEB. (Part# AC74H02101)

(Link to the Field Service Manual)