C3201 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3201: Fusing motor failure to turn |
Rank | B |
Trouble detection condition | The control circuit detects motor failure to turn while the motor is turning. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Fusing motor (M3) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
- Check the M3 for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M3 load check
- Check code: 45
- Multi code: 1, 2, 3, 4, 6 (bizhub C650i), 1, 3, 4, 6 (bizhub C550i), 1, 2, 4, 6 (bizhub C450i)
- Control signal: BASEB CN19EA-6 to 10
- Location of electrical component: 1-C
- Replace M3. (Part# AA2JM11100)
- Replace the fusing unit. (C650i/C550i Part# AA7NR70200 / C450i Part# AA7RR70700)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
L.3.10.3 (Link to the Field Service Manual)