How Can We Help?
C3202 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C3202: Fusing motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | • Fusing motor (M3) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
- Check the loading status of the fusing unit drive, and correct the error as necessary.
- Check CPUB for proper installation and correct as necessary.
- M3 load check
- Check code: 45
- Multi code: 1, 4, 5, 6
- Control signal: BASEB CN19EA-6 to 10
- Location of electrical component: 1-C
- Replace M3. (Part# AA2JM11000)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.9.2 (Link to the Field Service Manual)